MF FASTENER INDUSTRIES LLC
Manufacturer of anchor bolts, studs & plate washers · Importer & stockist of fasteners
Technical datasheet
DIN 975 / DIN 976-1 — Threaded bar, metric coarse
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Reference only — for design, verification or
contractual purposes refer to the current issue of the original standard.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
HOME /
DATA & DRAWINGS /
DIN 975
Dimensional datasheet
DIN 975 threaded barFully threaded rod, metric coarse, supplied in standard lengths and cut to size. Used for hangers, supports, tie rods, U-bolt replacements and anywhere a bolt of non-standard length is needed. Also called studding or all-thread. d nominal thread diameterP thread pitchL bar length
DimensionsmillimetresMetric coarse thread, tolerance 6g as standard. Weights are for carbon steel at 7.85 g/cm³ and are close enough for freight and packing; treat them as approximate.
Design from the stress area, not the diameterLoad capacity is calculated on the tensile stress area. M12 at 84.3 mm² in class 8.8 gives roughly 50 kN at proof load. Apply your own design factor — this sheet is not a design calculation. Threaded bar is not a stud boltFlanged joints in pipework and pressure vessels normally call for a stud bolt to ASTM A193 B7 with A194 2H nuts — controlled alloy, heat treated, certified against the heat number. DIN 975 bar is not the same product. If the drawing says B7, order B7. Property classesISO 898-1
Much commercial threaded bar is class 4.8 and unmarked. If the application is load-bearing, specify the class and ask for the certificate — do not assume. At a glance
SupplyThreaded bar is imported and held in stock. Stud bolts and bar cut to your drawing are manufactured at our own plant — cut, threaded, chamfered and coated to the length you specify. A cut bar will not take a nut cleanly unless the end is dressed, so tell us the finished length rather than cutting on site. Materials and finish
Galvanized bar needs an oversize-tapped galvanized nut. Order them together — a plain nut will not run onto a galvanized thread. TestingDimensional and thread inspection is carried out in our own plant on calibrated instruments. Tensile, hardness and chemical testing is carried out by independent UAE-accredited laboratories. Reference onlyThis datasheet is published for reference. Dimensions and property values are reproduced in good faith from published standards, but for design, verification or contractual purposes always refer to the current issue of the original standard. If a figure here conflicts with the standard, the standard governs. Need a quotation?Send the size, class, coating, finished length and quantity. If the bar is going into a flanged joint, send the piping specification instead — it may call for B7. |